Model |
Product Model |
MV-CL042-91CC |
Type |
4k Camera Link Line Scan Cameras,Color |
Performance |
Sensor type |
CMOS |
Pixel size |
7 μm |
Resolution |
4096 × 2 |
Image mode |
Supports 1-line |
Max. line rate |
40 kHz @ Mono 8 (Base), 50 kHz @ RGB 8 (80-bit), 100 kHz @ Bayer RGBG 8 (Full) |
Configuration mode |
Mono 8: Base RGB 8: Base, Medium, 80-bit Bayer RGBG 8: Base, Medium, Full |
Tap geometry |
Mono 8: 1 × RGB 8: 1 ×, 1 × 2, 1 × 10 Bayer RGBG 8: 1 × 2, 1 × 4, 1 × 8 |
Tap number |
Mono 8: 2 Taps RGB 8: 1/2/10 Taps Bayer RGBG 8: 2/4/8 Taps |
Pixel clock |
40 MHz, 60 MHz, 70 MHz, 85 MHz |
Dynamic range |
65.6 dB |
SNR |
40 dB |
Gain |
Supports 1.0 ×, 1.4 ×, 1.6 ×, 2.4 ×, 3.2 × |
Exposure time |
5 μs to 10 ms |
Exposure mode |
Off/ Once/ Continuous exposure mode; supports fixed time exposure, trigger-width exposure |
Mono/color |
Color |
Pixel format |
Mono 8, RGB 8, Bayer RGBG 8 |
Binning |
Supports 1 × 1, 1 × 2, 1 × 4, 2 × 1, 2 × 2, 2 × 4, 4 × 1, 4 × 2, 4 × 4 |
Reverse image |
Supports horizontal reverse image output |
Trigger mode |
External trigger, internal trigger |
External trigger mode |
Line trigger, frame trigger, line + frame trigger |
Electrical feature |
Data interface |
Camera Link (SDR connector); USB interface for updating firmware |
Digital I/O |
12-pin P10 connector provides power and I/O: configurable input/output × 4 (Line 0/1/3/4) and support single-ended/differential. Camera Link provides I/O (CC1/CC2/CC3/CC4). |
Power supply |
12 VDC to 24 VDC |
Power consumption |
Typ. 6.1 W@12 VDC |
Mechanical |
Lens mount |
M42*1, optical back focal length: 12 mm (0.5"), applicable to F-mount, C-mount and lens of other types via lens adapter |
Dimension |
62 mm × 62 mm × 36.9 mm (2.4" × 2.4" × 1.5") |
Weight |
Approx. 238 g (0.5 lb.) |
Ingress protection |
IP40 (under proper lens installation and wiring) |
Temperature |
Working temperature: -20 °C to 55 °C (-4 °F to 131 °F) Storage temperature : -30 °C to 80 °C (-22 °F to 176 °F) |
Humidity |
5% RH to 95% RH, no condensation |
General |
Client software |
MVS and frame grabber software meeting with Camera Link Protocol |
Operating system |
32/64-bit Windows XP/7/10/11 |
Compatibility |
Camera Link V1.2, GenICam |
Certification |
CE, RoHS, KC |